產(chǎn)品詳情
HG56e/1155-4S HGX6/1240-4 HG6/1080-4S
福州天行健16年專業(yè)德國GEA-Bock原廠船用壓縮機(jī)及零部件
福州天行健節(jié)能科技有限公司專業(yè)提供進(jìn)口船舶零部件
HG sin-tage compressors
The HG model series consists of state-of-the-art classical suction gas-cooled compressor technology.
Special features:
- Outstanding running comfort
- Efficiency and reliability on the highest level of quality
- Service-friendly, e.g. replaceable drive motors
- Oil pump lubrication
- Electronic motor protection
- Suitable for conventional or chlorine-free HFC refrigerants
HG…e
Those compressors are efficiency optimised models.
By technical optimisations the motor-efficiency, gas flow and efficiency of the valve system are improved.
Technical data
HGX66e/1750-4 S
Application Refrigeration & AC
Compressor refrigeration capacity 83.60 kW
Power consumption 25.40 kW
Current draw (400 V) 53.30 A
Mass flow 0.584 kg/s
at following operating condition:
Refrigerant R134a
Reference temperature Dew point
Evaporating temperature 5.0 °C
Condensing temperature 50.0 °C
Supply frequency 50 Hz
Voltage 400 V
Suction gas temperature 20 °C
Subcooling (outside cond.) 0 K
Number of cylinders / Bore / Stroke 6 / 80 mm / 58 mm
Displacement 50/60 Hz (1450/1740 1/min) 152,2 / 182,6 m3/h
Voltage 1) 380-420V Y/YY -3- 50Hz PW
440-480V Y/YY -3- 60Hz PW
Winding divided into 50% / 50%
Max. working current 2) 86.8 A
Max. power consumption 2) 50.7 kW
Starting current (rotor blocked) 2) 222.0 / 361.0 A
Motor protection INT69 G
Protection terminal box IP 66
Weight 282 kg
Max. permissible overpressure (g) (LP/HP) 3) 19 / 28 bar
Connection suction line SV 54 mm - 2 1/8 "
Connection discharge line DV 42 mm - 1 5/8 "
Lubrication Oil pump
Oil type R134a, R404A, R407A/C/F, R448A, R449A, R450A, R513A BOCKlub E55
Oil type R22 BOCKlub A46
Oil charge 4,4 Ltr.
Oil sump heater 230 V - 1 - 50/60 Hz, 160 W
Dimensions Length / Width / Height 810 / 557 / 467 mm
Sound power level LWA 4) 89 db(A) @ -35/+40 °C
86 db(A) @ -10/+45 °C
86 db(A) @ +5/+50 °C
Sound pressure level LpA 4) 75 db(A) @ -35/+40 °C
72 db(A) @ -10/+45 °C
72 db(A) @ +5/+50 °C
Scope of supply
Semi-hermetic six-cylinder reciprocating compressor with drive motor for part winding start
Single-section compressor housing with hermetically integrated electric motor
Oil pump
Winding protection with PTC resistor sensors and electronic trigger unit INT69 G
115-230 V AC, 50/60 Hz, IP00
Rear bearing flange prepared for oil differential pressure sensor DELTA-P II
Possibility of connection of oil level controllers ESK, AC+R or CARLY
Possibility of connection of oil level controllers Traxoil 5)
Oil charge:
HG: BOCKlub A46
HGX: BOCKlub E55
Sight glass
Internal safety valve
Suction and discharge line valve
Inert gas charge
4 anti-vibration pads enclosed
Accessories
Start unloader by means of a ESS (Electronic Soft Start), 400 V - 3 - 50/60 Hz, IP20 (Connection clamps IP00) for installation in switch cabinet 6)
Capacitiy regulator 110 V - 1 - 50/60 Hz, IP65
1-2 capacity regulator = 66/33% residual capacity 7)
Capacity regulator 230 V - 1 - 50/60 Hz, IP65
1-2 capacity regulator = 66/33% residual capacity 7)
Cylinder cover prepared for capacity regulator 8)
Oil sump heater 230 V - 1 - 50/60 Hz, 160 W 8)
Thermal protection thermostat per cylinder cover 8)
Oil pressure safety switch MP54 230 V - 1 - 50/60 Hz, IP20 6)
Oil temperature sensor (Pt1000, for external buation) 8)
Oil service valve
Oil differential pressure sensor DELTA-P II 220-240 V - 1 - 50/60 Hz 6)
Connection piece suction and discharge valve in welding design
USB converter for INT69 G Diagnose 6)
INT69 G Diagnose 115-230 V AC, 50/60 Hz, IP00 (INT69 G not applicable) 8)
DP-Modbus Gateway 115-230 V AC, 50/60 Hz, IP00 including adapter cable 6)
Modbus-LAN Gateway 230 V AC, 50/60 Hz, IP00 6)
Additional fan
230 V AC - 1 - 50 Hz, 97 W, IP44
230 V AC - 1 - 60 Hz, 128 W 6)
Step protection 6)
Injection nozzle 6)
Special voltage and/or frequency (on request)
Notes
1) Tolerance (± 10%) relates to the mean value of the voltage range. Other voltages and current types on request
All data are based on voltage rms values
PW = part winding, motors for part winding starting
(no start unloaders required)
Designs for Y/D on request
2) - The stated value for the max. power consumption is valid for the adjusted power supply.
- Starting current (rotor blocked):
Part winding (PW) motors: Winding 1 / Winding 1+2
Delta/Star (Δ/Y) motors: Δ / Y
- Take account of the max. operating current / max. power consumption for designing fuses, supply lines and safety devices. Fuse: Consumption category AC3.
3) LP = Low pressure
HP = High pressure
4) Declared dual-number noise emission values are in accordance with ISO 4871. The corresponding uncertainty to the sound power level is KWA = 2,5 dB and to the sound pressure level is KpA = 2,5 dB. The values are valid for 50 Hz with the refrigerant R404A at the standard rating points according to EN 12900.
A-weighted sound power level LWA (re 1 pW), in decibel. To determine the values, measurement bs of the ISO 3740 standard with accuracy class 2 or higher were used .
A-weighted sound pressure level LpA (re 20 μPa), in decibel. The values are calculated from the sound power level in accordance with ISO 11203: LpA = LWA - Q2 at a distance of d = 1m to the reference box.
5) Only with additional adapter possible
6) Enclosure
7) Capacity regulator premounted, control unit enclosed
8) Mounted